Experiments Implemented
Use the following table to determine which instrument to use for different experiments. This table reflects the experiments that have been setup and tested and for which a parameter set exists. This table is not complete; others are available. To see a complete list of experiments that have been setup and tested on each spectrometer, type rpar *.top from within Topspin while using the NMR.
Those highlighted experiments have links to additional information about the technique.
- Experiment
- Variable Temperature
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- yes
- Experiment
PROTON EXPERIMENTS
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- COSY
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- yes
- Experiment
- J-Resolved
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- NOESY /w ZQ suppression
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- ROESY
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- EASY-ROESY (TOCSY suppressed)
- 500 Ascend
- yes
- 500
- 400SL
- 400
- 300NB
- Experiment
- TOCSY
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- Homonuclear decoupling
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- 1H T1 Measurement
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- 300NB
- Experiment
- Kinetics
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- EXESY
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- 1D Magnetization Exchange
- 500 Ascend
- yes
- 500
- yes
- 400SL
- 400
- 300NB
- Experiment
- Diffusion and DOSY
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- 300NB
- Experiment
- STD (ligand binding)
- 500 Ascend
- yes
- 500
- 400SL
- 400
- 300NB
- Experiment
- 1D Water Suppression (Excitation Sculpting)
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- 300NB
- Experiment
CARBON-PROTON 2D
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- HSQC, HMBC
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- PURE-SHIFT HSQC
- 500 Ascend
- yes
- 500
- yes
- 400SL
- 400
- 300NB
- Experiment
- HSQC-TOCSY
- 500 Ascend
- yes
- 500
- yes
- 400SL
- yes
- 400
- 300NB
- Experiment
- ADEQUATE
- 500 Ascend
- yes
- 500
- yes
- 400SL
- 400
- 300NB
- Experiment
X-X or X-PROTON 2D
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 15N-1H HMBC
- 500 Ascend
- yes
- 500
- 400SL
- 400
- 300NB
- Experiment
- 15N-1H HSCC /w H2O SUPRESSION
- 500 Ascend
- yes
- 500
- 400SL
- 400
- 300NB
- Experiment
- 29Si-1H HMQC
- 500 Ascend
- 500
- yes
- 400SL
- yes
- 400
- 300NB
- Experiment
- 31P-1H HMQC
- 500 Ascend
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- Experiment
- 31P-31P COSY
- 500 Ascend
- 500
- 400SL
- yes
- 400
- 300NB
- Experiment
- 19F-13C HMQC
- 500 Ascend
- 500
- 400SL
- yes
- 400
- 300NB
- Experiment
X 1D and Other Experiments
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- DEPT
- 500 Ascend
- 500
- yes
- 400SL
- yes
- 400
- yes
- 300NB
- yes
- Experiment
- Solid-state NMR (HCN only)
- 500 Ascend
- 500
- 400SL
- yes
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB
- Experiment
- 500 Ascend
- 500
- 400SL
- 400
- 300NB